Indication LEDs: Red power LED / Blue charge complete LED
Protection: No fault indication LED. No onboard battery protection circuitry.
Dimensions: ~(34.5mm x 15mm x 4.8mm)
Operation Overview
If the connected battery voltage is below 3.0V, the charger provides a 100mA trickle charge until the battery reaches 3.0V
Once the battery reaches 3.0V, the charger switches to CC (Constant Current) mode and charges at the preset current limit
Refer to the product image for the current-setting resistor location. Default (47kΩ) – 3A; open circuit – 2.1A; 135kΩ – 1A
Constant Current mode continues until the battery voltage approaches 4.2V and the charge current drops to approximately 300mA. The charger then switches to CV (Constant Voltage) mode
In CV mode, charging pauses every 4 minutes to check whether the battery voltage exceeds 4.15V. If the battery is full, charging stops. If not, charging resumes for another 4 minutes before checking again.
After full charge is detected, charging will resume only if the battery voltage drops below 4.1V